Omnipod 5 Libre2 Plus G6 Pods coupons
Omnipod 5 Libre2 Plus G6 Pods

Omnipod 5 Libre2 Plus G6 Pods Coupons & Savings Card – Discount Prices from $1802.73

The Omnipod 5 Automated Insulin Delivery System now integrates with both the FreeStyle Libre 2 Plus and Dexcom G6 continuous glucose monitoring (CGM) sensors, offering users flexibility in their diabetes management. This integration allows for tubeless, automated insulin delivery, with the convenience of a 15-day sensor wear for the FreeStyle Libre 2 Plus. Users can start, deactivate, and view sensor glucose data directly from the Omnipod 5 Controller. To utilize this system, patients need to ensure they have the compatible Omnipod 5 Pods and a separate prescription for the FreeStyle Libre 2 Plus Sensor. It's important to note that Omnipod 5 is not compatible with FreeStyle Libre 2, FreeStyle Libre 3, or FreeStyle Libre 3 Plus Sensors. (, )
Our Omnipod 5 Libre2 Plus G6 Pods coupons are free to use. You can print the coupon, email it to yourself, or receive the Omnipod 5 Libre2 Plus G6 Pods coupon via text message. To get your free discount, show the pharmacist your Omnipod 5 Libre2 Plus G6 Pods savings card which has the discounted coupon price. Use our filters below to edit the prescription box to match your needs. The Omnipod 5 Libre2 Plus G6 Pods prices will update based on your prescription needs. Above our Omnipod 5 Libre2 Plus G6 Pods coupons, you can change the location to see pharmacy prices in other areas. Our prescription discount card will update online with the specific pharmacy costs associated with your edits. Be sure to text, email, or print the Omnipod 5 Libre2 Plus G6 Pods savings card code that you need after editing the prescription box and location field. Show the discount card to your pharmacist before paying.

My prescription

Edit

1, Omnipod 5 Libre2 Plus G6 Pods (30 Miscellaneous)

Select pharmacy

Pharmacy logo

CVS

$1802.73

COUPON PRICE
Pharmacy logo

Walgreens

$1869.43

COUPON PRICE
Pharmacy logo

Albertsons

$1890.08

COUPON PRICE
Pharmacy logo

Walmart

$1917.55

COUPON PRICE

Omnipod 5 Libre2 Plus G6 Pods savings card

Show this card to your pharmacist
Pharmacy logo

CVS

$1802.73

BIN

ID

PCN

GRP

019876

LHD75D4E86

CHIPPO

LHX

Powered by

This card is not insurance

Price history for Omnipod 5 Libre2 Plus G6 Pods

30 Miscellaneous, 1

Average retail price for Omnipod 5 Libre2 Plus G6 Pods

Average SaveHealth price for Omnipod 5 Libre2 Plus G6 Pods

Our price history data is based on aggregated prescription data collected from participating pharmacies in America. Our prescription data updates daily to reflect the latest price changes. If you notice a missing data point, it means there wasn't sufficient data available to generate a monetary value for that date.

*Retail prices are based on pharmacy claims data, and may not be accurate when we don't have enough claims.

Omnipod 5 Libre2 Plus G6 Pods dosage forms

Use our Omnipod 5 Libre2 Plus G6 Pods 1 coupon with prices from $5432.19 for 90 Miscellaneous. You can also use our Omnipod 5 Libre2 Plus G6 Pods 1 coupon with prices from $3617.46 for 60 Miscellaneous. We have a Omnipod 5 Libre2 Plus G6 Pods 1 coupon with prices from $1802.73 for 30 Miscellaneous.
DosageQuantityPrice fromPer unit
190 Miscellaneous$5432.19$60.36
160 Miscellaneous$3617.46$60.29
130 Miscellaneous$1802.73$60.09
Show more dosage forms >

Omnipod 5 Libre2 Plus G6 Pods Warnings

When using the Omnipod 5 System with the FreeStyle Libre 2 Plus or Dexcom G6 sensors, it's important to be aware of certain risks to ensure safe and effective insulin delivery:

Device Compatibility and Environmental Conditions

  • Medical Procedures: Before undergoing medical imaging procedures such as X-rays, MRIs, or CT scans, remove the Pod, sensor, and transmitter, and place the controller outside the procedure room. Exposure to strong radiation or magnetic fields can damage these components.

  • Atmospheric Pressure: Avoid using the system at high elevations (above 10,000 feet) or in environments with high atmospheric pressure, such as hyperbaric chambers. Changes in pressure can affect insulin delivery, potentially leading to hypoglycemia or hyperglycemia.

  • Oxygen-Rich Environments: Do not use the system in environments with high oxygen levels, like certain surgical areas or hyperbaric chambers, as this could pose a fire hazard.

Insulin Delivery Risks

  • Insulin Compatibility: Use only rapid-acting U-100 insulins such as NovoLog, Humalog, or Admelog with the Omnipod 5 System. Using other types of insulin may result in improper insulin delivery.

  • Manual Insulin Administration: Avoid administering insulin via injection or inhalation while wearing an active Pod, as the system cannot account for insulin delivered outside of it, increasing the risk of hypoglycemia.

  • Interrupted Insulin Delivery: Be prepared to administer insulin through alternative methods if the Pod stops working. Interruptions can lead to high blood glucose levels or diabetic ketoacidosis (DKA).

Device Handling and Maintenance

  • Charging Equipment: Use only the charging adapter and cable provided with the Omnipod 5 Controller. Using unauthorized accessories may lead to overheating, posing a fire risk.

  • Device Inspection: Regularly check the charging port and cable for signs of damage, such as melting or discoloration. If any issues are detected, discontinue use and contact customer support.

  • Environmental Exposure: Protect the system from extreme temperatures and direct sunlight, as these conditions can affect device functionality and insulin efficacy.

User Considerations

  • Sensory Limitations: Ensure you have adequate vision and hearing to recognize all system alerts and alarms. If you have impairments, consult with your healthcare provider to determine if the system is suitable for you.

  • Medical Conditions: The safety of the Omnipod 5 System has not been evaluated in pregnant women, critically ill patients, or those on dialysis. Consult your healthcare provider if any of these conditions apply to you.

By adhering to these guidelines and maintaining open communication with your healthcare provider, you can minimize risks and ensure the safe use of the Omnipod 5 System with your continuous glucose monitoring device.

Omnipod 5 Libre2 Plus G6 Pods Side Effects

When using the Omnipod 5 insulin delivery system and Dexcom G6 continuous glucose monitor (CGM), it's important to be aware of potential side effects to ensure safe and effective diabetes management. Skin Reactions Some users have reported skin reactions at the sites where the Omnipod 5 pods and Dexcom G6 sensors are applied. These reactions can include redness, swelling, itching, and, in some cases, blistering. For certain individuals, these symptoms may indicate a hypersensitivity or allergic reaction to the adhesive used in these devices. Once sensitized, the skin may react more quickly and severely upon subsequent applications. If you experience such reactions, consult your healthcare provider to discuss alternative options or management strategies. Infections Improper application or prolonged use of the Omnipod 5 pod can lead to skin infections at the infusion site. Signs of infection include redness, swelling, warmth, pain, and discharge. To minimize this risk, always follow proper aseptic techniques during pod application, such as washing your hands and cleaning the infusion site. If you notice signs of infection, remove the pod and seek medical attention promptly. Device Malfunctions There have been reports of the Omnipod 5 controller's charging port and cable overheating, which could potentially cause burns or fire. Users are advised to monitor their devices for signs of overheating and to use only the provided charging equipment. Additionally, some users have experienced issues with the Dexcom G6 sensor providing inaccurate glucose readings, which can lead to inappropriate insulin dosing. It's crucial to cross-reference sensor readings with blood glucose meter results, especially if symptoms don't align with the sensor data. Medication Interference Certain medications, such as hydroxyurea, can interfere with the accuracy of Dexcom G6 sensor readings, leading to falsely elevated glucose values. This can result in inappropriate insulin dosing and increase the risk of hypoglycemia. If you're taking hydroxyurea or other medications, inform your healthcare provider to determine the best glucose monitoring approach. Hypoglycemia and Hyperglycemia Inaccurate sensor readings or device malfunctions can lead to improper insulin delivery, increasing the risk of both low (hypoglycemia) and high (hyperglycemia) blood sugar levels. Symptoms of hypoglycemia include sweating, shaking, confusion, and dizziness, while hyperglycemia may cause increased thirst, frequent urination, and fatigue. Regularly monitor your blood glucose levels and be attentive to any symptoms to manage these risks effectively. By staying informed about these potential side effects and maintaining open communication with your healthcare provider, you can enhance the safety and effectiveness of your diabetes management regimen.

Omnipod 5 Libre2 Plus G6 Pods Interactions

The Omnipod 5 Automated Insulin Delivery (AID) System is designed to work seamlessly with both the Dexcom G6 and the FreeStyle Libre 2 Plus continuous glucose monitoring (CGM) sensors. This integration allows for automated insulin delivery based on real-time glucose readings, enhancing diabetes management.

Compatibility and Pod Selection

It's essential to use the correct Pods that are compatible with your chosen CGM sensor:

  • Dexcom G6 and G7 Sensors: Omnipod 5 Pods compatible with both Dexcom G6 and G7 sensors are available.

  • FreeStyle Libre 2 Plus Sensor: There are specific Omnipod 5 Pods designed to work with the FreeStyle Libre 2 Plus sensor.

To identify the appropriate Pods, check the top right-hand corner of the Pod box or the Pod tray lid for compatibility information. Before switching sensors, consult with your healthcare professional to discuss the change, obtain a prescription for the new sensor, and receive necessary training. Ensure you have used your existing Pods and sensors before transitioning to a new sensor type.

Integration with FreeStyle Libre 2 Plus Sensor

The integration of Omnipod 5 with the FreeStyle Libre 2 Plus sensor offers several benefits:

  • Extended Sensor Wear: The FreeStyle Libre 2 Plus sensor provides a 15-day wear period, reducing the frequency of sensor changes.

  • Unified Control: Users can manage both the Pod and sensor directly from the Omnipod 5 App on the dedicated Controller.

To use Omnipod 5 in Automated Mode with the FreeStyle Libre 2 Plus sensor, a separate prescription for the sensor is required. It's important to note that Omnipod 5 is not compatible with FreeStyle Libre 2, FreeStyle Libre 3, or FreeStyle Libre 3 Plus sensors.

Considerations for Users

Some users have reported connectivity issues between the Omnipod 5 and the FreeStyle Libre 2 Plus sensor, potentially due to Bluetooth signal challenges. To maintain a stable connection, it's recommended to wear the Pod and sensor in close proximity, ideally within line of sight. Additionally, be aware that the Omnipod 5 System with FreeStyle Libre 2 Plus does not currently support follower apps, which may be a consideration for caregivers or those who rely on remote monitoring.

Before making any changes to your diabetes management system, consult with your healthcare provider to determine the best options tailored to your individual needs.

Omnipod 5 Libre2 Plus G6 Pods FAQs
Does Omnipod 5 work with Libre 2 Plus?

The Omnipod 5 system is designed to work with the Dexcom G6 continuous glucose monitor. It does not integrate with the Libre 2 Plus. Users would need to use the Libre 2 Plus independently from the Omnipod 5 system.

Yes, the Omnipod 5 is designed to work with the Dexcom G6 continuous glucose monitoring system. This integration allows for automated insulin delivery based on glucose readings from the Dexcom G6.

There could be several reasons why the Omnipod 5 is not connecting to the Dexcom G6. It is important to ensure that both devices are within the recommended range for connectivity. Additionally, both devices should have Bluetooth enabled and be running the latest software updates. Checking for any interference from other electronic devices and ensuring that both devices are properly paired can also help resolve connectivity issues. If the problem persists, consulting the user manuals or contacting customer support for both devices may provide further assistance.

As of the latest information available, the Dexcom G6 is not being discontinued. It remains a widely used continuous glucose monitoring system. However, Dexcom has introduced newer models, such as the Dexcom G7, which may lead to changes in availability or support for older models over time. It is advisable to check with Dexcom or healthcare providers for the most current information.

There could be several reasons why the Omnipod 5 is not connecting to the transmitter. It is important to ensure that both devices are within the recommended range for connectivity. Additionally, checking that both devices have sufficient battery life and are not experiencing any technical issues is crucial. Restarting both the Omnipod 5 and the transmitter can sometimes resolve connectivity issues. If the problem persists, consulting the device's user manual or contacting customer support for further assistance is advisable.