Relion Premier Test Coupons & Savings Card – Discount Prices from $7.19
My prescription
Edit
1, Relion Premier Test (30 Strips)
Select pharmacy

Walgreens
$7.19
COUPON PRICERelion Premier Test savings card
Show this card to your pharmacist
Walgreens
$7.19
BIN
ID
PCN
GRP
019876
LHBC48BD4E
CHIPPO
LHX
Powered by
Price history for Relion Premier Test
30 Strips, 1
Average retail price for Relion Premier Test
Average SaveHealth price for Relion Premier Test
Our price history data is based on aggregated prescription data collected from participating pharmacies in America. Our prescription data updates daily to reflect the latest price changes. If you notice a missing data point, it means there wasn't sufficient data available to generate a monetary value for that date.
*Retail prices are based on pharmacy claims data, and may not be accurate when we don't have enough claims.
Relion Premier Test dosage forms
Dosage | Quantity | Price from | Per unit |
---|---|---|---|
1 | 30 Strips | $7.19 | $0.24 |
Relion Premier Test Warnings
When using the ReliOn Premier blood glucose monitoring system, it's important to be aware of certain safety considerations to ensure accurate readings and maintain your health:
Single-Use Only: Test strips are designed for one-time use. Reusing them can lead to inaccurate results.
Personal Use: The meter and lancing device are intended for a single user. Sharing these devices, even with family members, can increase the risk of transmitting infectious diseases.
Biohazard Precautions: Components that come into contact with blood are considered biohazardous. Proper disposal of used test strips and lancets is essential to prevent potential transmission of infectious diseases.
Storage Conditions: Store test strips in their original vial at temperatures between 34–86°F (1–30°C) and relative humidity of 20–80%. Exposure to extreme temperatures or humidity can affect their performance.
Sample Collection: Use only fresh capillary whole blood samples. Do not use serum, plasma, or venous whole blood, as this can lead to inaccurate readings.
Health Conditions: Certain conditions, such as severe dehydration, hypotension, shock, or hyperglycemic-hyperosmolar state, can affect test results. If you have any of these conditions, consult your healthcare professional before using the device.
Environmental Factors: The system may not function properly at altitudes above 10,000 feet (3,048 meters). Additionally, avoid using the device in environments with high humidity or extreme temperatures.
Control Solution Testing: Regularly check the system's accuracy using the ReliOn Premier Control Solution, especially when opening a new vial of test strips or if you suspect the meter or test strips are not functioning correctly.
By adhering to these guidelines, you can help ensure the reliability of your blood glucose readings and maintain safe testing practices.
Relion Premier Test Side Effects
The ReliOn Premier Blood Glucose Monitoring System is designed to help individuals with diabetes monitor their blood sugar levels accurately. While the device itself does not cause side effects, certain factors can influence the accuracy of your readings, which may impact your diabetes management. Factors Affecting Accuracy:
- Hematocrit Levels: An unusually high or low red blood cell count can lead to inaccurate results. It's important to be aware of your hematocrit range and consult your healthcare provider if you have concerns.
- Severe Dehydration: Excessive loss of body fluids may cause falsely low blood glucose readings. If you suspect severe dehydration, seek medical attention promptly.
- Altitude: Using the device at elevations above 10,000 feet (3,048 meters) may affect test strip performance, potentially leading to inaccurate readings.
- Medical Conditions: Individuals experiencing severe low blood pressure, shock, or a hyperosmolar state (with or without ketosis) may receive inaccurate results. Best Practices for Accurate Readings:
- Proper Storage: Store your meter and test strips in a cool, dry place, avoiding areas with high humidity, such as bathrooms or kitchens.
- Single-Patient Use: The ReliOn Premier system is intended for use by one person only. Sharing the device can lead to cross-contamination and inaccurate readings.
- Regular Performance Checks: Use ReliOn Premier Control Solutions to verify that your meter and test strips are functioning correctly. Perform these checks when:
- Using the meter for the first time.
- Starting a new vial of test strips.
- Suspecting the meter or test strips are not working properly.
- Experiencing test results that do not match how you feel.
- After the meter has been dropped or damaged. If control solution test results fall outside the expected range, it may indicate issues such as user error, expired or contaminated control solution, or damaged test strips. In such cases, do not use the system and contact Customer Service for assistance. By adhering to these guidelines and being aware of factors that can affect your blood glucose readings, you can ensure more accurate monitoring and better manage your diabetes.
Relion Premier Test Interactions
The ReliOn™ Premier Blood Glucose Monitoring System is designed to provide accurate blood glucose readings when used correctly. However, certain factors can interfere with its performance, leading to inaccurate results. It's important to be aware of these potential interferences to ensure reliable monitoring.
Hematocrit Levels: The system may produce inaccurate results if your hematocrit (the proportion of red blood cells in your blood) is abnormally high or low. Specifically, a hematocrit level over 60% or below 20% can affect the accuracy of your readings.
Medical Conditions: Individuals who are severely hypotensive (experiencing very low blood pressure) or in shock may receive inaccurate results from the system. Additionally, those experiencing a hyperglycemic-hyperosmolar state, with or without ketosis, may also encounter inaccuracies. Critically ill patients should not use this system for blood glucose testing.
Environmental Factors: The system operates optimally within specific temperature and humidity ranges. Ensure that both the meter and test strips are used and stored in environments with temperatures between 50–104°F (10–40°C) and relative humidity between 10–90%. Exposure to conditions outside these ranges can lead to erroneous readings.
Sample Integrity: For accurate results, use only fresh capillary whole blood samples. Do not use serum, plasma, or venous whole blood. Ensure that the blood sample is sufficient in volume and not contaminated, as inadequate or contaminated samples can affect the test outcome.
Test Strip Compatibility: Use only ReliOn™ Premier Blood Glucose Test Strips with the ReliOn™ Premier meter. Using incompatible test strips can result in inaccurate readings.
Control Solution Testing: Regularly perform control solution tests to verify that the meter and test strips are functioning correctly. Use only ReliOn™ Premier Control Solutions for this purpose. If control solution test results fall outside the expected range, do not use the system for blood glucose testing until the issue is resolved.
By being mindful of these factors and following the recommended guidelines, you can help ensure the accuracy and reliability of your blood glucose measurements with the ReliOn™ Premier system.
Are ReliOn premier test strips accurate?
ReliOn Premier test strips are generally considered accurate for monitoring blood glucose levels. They are designed to meet the accuracy standards set by regulatory agencies. However, as with any glucose monitoring system, it is important to follow the manufacturer's instructions carefully and ensure the meter and strips are used correctly for the most reliable results. Regular calibration and proper storage of the strips can also help maintain their accuracy.
What test strips work with ReliOn Premier?
ReliOn Premier test strips are specifically designed to work with ReliOn Premier family of blood glucose meters, including the ReliOn Premier Classic, ReliOn Premier Voice, and ReliOn Premier BLU meters. It is important to use the correct test strips to ensure accurate readings.
Does ReliOn need to be calibrated?
ReliOn glucose meters typically do not require calibration by the user. They are designed to be used with test strips that are pre-calibrated. However, it is important to follow the manufacturer's instructions for use and ensure that the meter and test strips are compatible. If there are any concerns about accuracy, it is advisable to consult the user manual or contact customer support for guidance.
Is the ReliOn Premier accurate?
The ReliOn Premier blood glucose meter is generally considered accurate and reliable for monitoring blood glucose levels. It meets the accuracy standards set by the FDA for over-the-counter blood glucose meters. However, as with any medical device, it is important to follow the manufacturer's instructions carefully and perform regular quality control checks to ensure optimal performance.