
Tens Therapy Replace Back Pads Coupons & Savings Card – Discount Prices from $170.55
My prescription
Edit
1, Tens Therapy Replace Back Pads (30 Miscellaneous)
Select pharmacy

Walgreens
$170.55
COUPON PRICETens Therapy Replace Back Pads savings card
Show this card to your pharmacist
Walgreens
$170.55
BIN
ID
PCN
GRP
019876
LH0ACD751A
CHIPPO
LHX
Powered by
Price history for Tens Therapy Replace Back Pads
30 Miscellaneous, 1
Average retail price for Tens Therapy Replace Back Pads
Average SaveHealth price for Tens Therapy Replace Back Pads
Our price history data is based on aggregated prescription data collected from participating pharmacies in America. Our prescription data updates daily to reflect the latest price changes. If you notice a missing data point, it means there wasn't sufficient data available to generate a monetary value for that date.
*Retail prices are based on pharmacy claims data, and may not be accurate when we don't have enough claims.
Tens Therapy Replace Back Pads dosage forms
Dosage | Quantity | Price from | Per unit |
---|---|---|---|
1 | 30 Miscellaneous | $170.55 | $5.69 |
Tens Therapy Replace Back Pads Warnings
When replacing the electrode pads on your TENS (Transcutaneous Electrical Nerve Stimulation) unit, it's essential to follow specific safety guidelines to minimize risks and ensure effective therapy. Here are key precautions to consider:
Proper Electrode Placement: Always position the electrode pads on or near the area of pain, ensuring they do not touch each other and are at least an inch apart. Avoid placing pads directly over the spine, joints, or bony prominences, as this can reduce effectiveness and may cause discomfort. Never place electrodes on the front of the neck, near the eyes, or over the heart, as stimulation in these areas can lead to serious complications.
Skin Condition: Before applying new pads, ensure the skin is clean, dry, and free from lotions or oils to promote good adhesion and conductivity. Do not place electrodes over broken, irritated, or numb skin, as this can increase the risk of skin irritation or burns.
Medical Conditions and Implants: Individuals with pacemakers, other implanted electronic devices, or metal implants should avoid using TENS therapy, as the electrical currents can interfere with these devices and potentially cause harm. If you have a history of epilepsy, consult your healthcare provider before using TENS, as improper use may trigger seizures.
Activity Restrictions: Do not use the TENS unit while sleeping, driving, or operating heavy machinery, as the electrical stimulation can cause sudden muscle contractions, leading to accidents or injuries. Additionally, avoid using the device in or near water to prevent electrical shock.
Device Maintenance: Regularly inspect your TENS unit and electrode pads for signs of wear or damage. Damaged equipment can malfunction, leading to ineffective treatment or increased risk of injury. Replace electrode pads as recommended by the manufacturer to maintain optimal performance.
By adhering to these safety precautions, you can effectively manage pain using TENS therapy while minimizing potential risks.
Tens Therapy Replace Back Pads Side Effects
Tens Therapy Replace Back Pads Interactions
To ensure your TENS therapy remains effective, it's important to properly maintain and replace the electrode pads used on your back. Over time, these pads can lose their adhesiveness and effectiveness due to factors like skin oils, dirt, and wear.
When to Replace TENS Unit Pads
Regular inspection of your TENS unit pads is essential. Signs that it's time to replace them include:
Loss of Stickiness: If the pads no longer adhere well to your skin, they won't deliver the electrical stimulation effectively.
Visible Wear and Tear: Look for curling edges, tears, or changes in the gel texture.
Reduced Effectiveness: If you notice a decrease in pain relief during your sessions, worn-out pads might be the cause.
Steps to Replace TENS Unit Pads
Turn Off the Device: Always ensure your TENS unit is powered off before handling the pads to prevent accidental shocks.
Remove the Old Pads: Gently peel the old pads off your skin. Avoid pulling on the wires to prevent damage.
Clean Your Skin: Before applying new pads, clean the area with mild soap and water to remove oils and lotions. Dry the skin thoroughly.
Attach the New Pads: Connect the new pads to the TENS unit cables as per the manufacturer's instructions. Remove any protective film from the pads and place them on the desired area, ensuring full contact with the skin.
Store Properly: After each use, place the protective film back on the pads and store them in a cool, dry place away from direct sunlight to maintain their adhesiveness.
Tips to Extend Pad Life
Apply to Clean, Dry Skin: This prevents oils and lotions from reducing the pads' stickiness.
Limit Wear Time: Avoid wearing the pads longer than recommended, as prolonged use can degrade the adhesive.
Clean Pads Gently: If the pads lose stickiness, lightly spraying the adhesive side with water can help rejuvenate them. Avoid using paper towels or cloths that might leave fibers behind.
By following these guidelines, you can ensure your TENS therapy remains effective and your pads last longer, providing consistent pain relief for your back.
Using the SaveHealth discount card, what is the price of Tens Therapy Replace Back Pads without insurance?
Using the SaveHealth discount card, the price of Tens Therapy Replace Back Pads without insurance is $170.55.
What is the price of Tens Therapy Replace Back Pads at Walgreens?
The price of Tens Therapy Replace Back Pads at Walgreens is $170.55. SaveHealth can help you save 71% on Tens Therapy Replace Back Pads at Walgreens.