
Fora V10 Blood Glucose Test Coupons & Savings Card – Discount Prices from $13.64
My prescription
Edit
1, Fora V10 Blood Glucose Test (30 Strips)
Select pharmacy

Walgreens
$13.64
COUPON PRICEFora V10 Blood Glucose Test savings card
Show this card to your pharmacist
Walgreens
$13.64
BIN
ID
PCN
GRP
019876
LH7F83BF34
CHIPPO
LHX
Powered by
Price history for Fora V10 Blood Glucose Test
30 Strips, 1
Average retail price for Fora V10 Blood Glucose Test
Average SaveHealth price for Fora V10 Blood Glucose Test
Our price history data is based on aggregated prescription data collected from participating pharmacies in America. Our prescription data updates daily to reflect the latest price changes. If you notice a missing data point, it means there wasn't sufficient data available to generate a monetary value for that date.
*Retail prices are based on pharmacy claims data, and may not be accurate when we don't have enough claims
Fora V10 Blood Glucose Test dosage forms
Dosage | Quantity | Price from | Per unit |
---|---|---|---|
1 | 30 Strips | $13.64 | $0.45 |
Fora V10 Blood Glucose Test Warnings
When using the Fora V10 Blood Glucose Monitoring System, it's essential to be aware of certain risks to ensure accurate readings and maintain your health:
Device Sharing and Infection Risk: The meter and lancing device are intended for single-patient use. Sharing these devices, even with family members, can lead to the transmission of infectious diseases.
Environmental Factors: Extreme temperatures, high humidity, or high altitude can affect the accuracy of your blood glucose readings. Always use the device within the recommended environmental conditions specified in the user manual.
Alternative Site Testing (AST): While the Fora V10 allows testing from sites other than the fingertip, such as the palm or forearm, be cautious. AST may not be suitable if your blood glucose levels are rapidly changing, such as after meals, exercise, or insulin administration. In such cases, fingertip testing is recommended for more accurate results.
Storage and Handling: Improper storage of the meter and test strips can lead to inaccurate readings. Store them in a cool, dry place, away from direct sunlight, and ensure the test strip vial is tightly closed after each use.
Health Conditions: Certain medical conditions, like severe dehydration, anemia, or high uric acid levels, can affect blood glucose readings. If you have any of these conditions, consult your healthcare provider to determine the best testing practices for you.
Medication Interference: Some medications, such as those containing acetaminophen (e.g., Tylenol), can interfere with blood glucose readings. Always inform your healthcare provider about any medications or supplements you're taking to ensure accurate monitoring.
By being mindful of these factors and following the manufacturer's guidelines, you can effectively manage your blood glucose levels and reduce potential risks associated with testing.
Fora V10 Blood Glucose Test Side Effects
The Fora V10 Blood Glucose Monitoring System is designed to be user-friendly and safe for regular blood glucose testing. While the device itself does not cause side effects, the process of obtaining a blood sample involves certain considerations:
- Discomfort at the Puncture Site: Using the lancing device to draw blood may cause mild pain or discomfort. To minimize this, it's advisable to use a new lancet for each test and to follow the lancing device's instructions carefully.
- Risk of Infection: Sharing the lancing device or lancets can increase the risk of spreading infectious diseases. Therefore, it's crucial to use these components for a single patient only and not share them with others.
- Skin Irritation: Repeated testing at the same site can lead to skin irritation or calluses. To prevent this, rotate testing sites regularly, choosing different fingers or alternative sites like the palm, forearm, or upper arm, as recommended. By adhering to proper hygiene practices and the manufacturer's guidelines, users can effectively manage their blood glucose levels while minimizing potential discomfort or risks associated with the testing process.
Fora V10 Blood Glucose Test Interactions
When using the FORA V10 Blood Glucose Monitoring System, it's important to be aware of factors that can influence the accuracy of your blood glucose readings. While the FORA V10 is designed to provide reliable measurements, certain conditions and substances may affect its performance.
Hematocrit Levels: The proportion of red blood cells in your blood, known as hematocrit, can impact glucose readings. Low hematocrit levels (below 30%) may lead to falsely high readings, while high levels (above 55%) can result in falsely low readings. If you're unsure about your hematocrit levels, consult your healthcare professional.
Alternative Site Testing (AST): The FORA V10 allows blood samples to be taken from areas other than the fingertips, such as the palm, forearm, or upper arm. However, AST may not be suitable for everyone. It's recommended to use AST only in specific situations, like when you're in a pre-meal or fasting state. Avoid AST if you've recently taken insulin, suspect low blood glucose, or if your readings don't match how you feel. Always consult your healthcare professional before using alternative sites for testing.
Sample Size and Application: Ensuring that the blood sample fully fills the test strip's confirmation window is crucial. An insufficient sample can lead to inaccurate results. Always follow the instructions provided with your meter for applying blood to the test strip.
Medications and Supplements: Certain medications and supplements can interfere with blood glucose measurements. For instance, high doses of Vitamin C (ascorbic acid) have been known to affect readings in some glucose monitoring systems. While specific interactions with the FORA V10 aren't detailed, it's advisable to be cautious. If you're taking high doses of vitamin C or other supplements, discuss potential interactions with your healthcare provider.
Environmental Factors: Extreme temperatures and humidity can affect the performance of your meter and test strips. Store your device and supplies in a cool, dry place, and avoid exposing them to direct sunlight or heat.
Regular Maintenance: Keep your meter clean and perform regular quality control tests using control solutions to ensure accurate readings. Always use fresh test strips and check their expiration dates.
By being mindful of these factors and following the guidelines provided with your FORA V10 system, you can help ensure accurate and reliable blood glucose measurements.
Using the SaveHealth discount card, what is the price of Fora V10 Blood Glucose Test without insurance?
Using the SaveHealth discount card, the price of Fora V10 Blood Glucose Test without insurance is $13.64.
What is the price of Fora V10 Blood Glucose Test at Walgreens?
The price of Fora V10 Blood Glucose Test at Walgreens is $13.64. SaveHealth can help you save 69% on Fora V10 Blood Glucose Test at Walgreens.