Freestyle Precision Neo System Coupons & Savings Card – Discount Prices from $23.80
My prescription
Edit
w/Device, Freestyle Precision Neo System (1 Kit)
Select pharmacy

Walgreens
$23.80
COUPON PRICEFreestyle Precision Neo System savings card
Show this card to your pharmacist
Walgreens
$23.80
BIN
ID
PCN
GRP
019876
LH10360E25
CHIPPO
LHX
Powered by
Price history for Freestyle Precision Neo System
1 Kit, w/Device
Average retail price for Freestyle Precision Neo System
Average SaveHealth price for Freestyle Precision Neo System
Our price history data is based on aggregated prescription data collected from participating pharmacies in America. Our prescription data updates daily to reflect the latest price changes. If you notice a missing data point, it means there wasn't sufficient data available to generate a monetary value for that date.
*Retail prices are based on pharmacy claims data, and may not be accurate when we don't have enough claims
Freestyle Precision Neo System dosage forms
Dosage | Quantity | Price from | Per unit |
---|---|---|---|
w/Device | 1 Kit | $23.80 | $23.80 |
Freestyle Precision Neo System Warnings
When using the FreeStyle Precision Neo system, it's important to be aware of certain safety considerations to ensure accurate readings and prevent potential issues:
Device Usage and Handling:
Use only FreeStyle Precision Neo test strips and accessories to maintain accuracy.
Avoid exposing the device to extreme temperatures or strong electromagnetic fields, as these can affect its performance.
Do not submerge the device in water or modify it in any way.
User Considerations:
The system is intended for in vitro diagnostic use only and is not suitable for veterinary purposes.
It is not recommended for individuals with certain allergies or sensitivities to device materials.
Storage and Maintenance:
Store test strips in their original packaging to maintain quality.
Handle the device with care to prevent damage, and adhere to the user manual instructions for proper use and maintenance.
By following these guidelines, users can help ensure the safe and effective operation of the FreeStyle Precision Neo system.
Freestyle Precision Neo System Side Effects
When using the Freestyle Precision Neo blood glucose monitoring system, some users may experience certain side effects, primarily related to the process of obtaining blood samples. These can include:
- Skin Irritation: Frequent testing may lead to redness, itching, or discomfort at the site where blood is drawn.
- Bruising: Occasionally, the area where the finger is pricked might develop mild bruising, which typically resolves on its own.
- Infection: If proper hygiene is not maintained or if lancet devices are shared, there is an increased risk of infection at the testing site. To minimize these risks, it's important to:
- Use only the lancet device and test strips designed specifically for the Freestyle Precision Neo system.
- Avoid sharing your lancet device or test strips with others to prevent infection.
- Keep the meter clean and dry, and avoid exposing it to moisture, extreme temperatures, or direct sunlight.
- Follow the manufacturer's instructions for proper use and maintenance of the device. Additionally, some users have reported issues with the device's performance, such as receiving erratic glucose readings or experiencing device malfunctions. These issues can potentially lead to symptoms like dizziness, weakness, headache, blurred vision, or, in severe cases, loss of consciousness due to inaccurate glucose readings. If you encounter any device-related problems or unusual symptoms, it's crucial to consult with your healthcare provider promptly.
Freestyle Precision Neo System Interactions
When using the FreeStyle Precision Neo blood glucose monitoring system, it's important to be aware of factors that can affect the accuracy of your glucose readings. Certain substances and conditions may interfere with the device's performance:
Vitamin C (Ascorbic Acid): High doses of vitamin C can falsely elevate glucose readings.
Aspirin (Salicylic Acid): Large amounts of aspirin may slightly lower glucose readings.
Xylose: This sugar, sometimes used in medical tests, can interfere with glucose measurements.
Hematocrit Levels: Abnormal hematocrit (the proportion of red blood cells in your blood) can impact the accuracy of glucose readings.
Oxygen Levels: High partial pressures of oxygen, such as those experienced during hyperbaric oxygen therapy, may affect the device's performance.
To ensure accurate readings:
Inform your healthcare provider about all medications and supplements you're taking.
Be cautious when using the device in environments with high oxygen levels.
If you suspect an inaccurate reading, perform a control solution test or consult your healthcare provider.
Always follow the manufacturer's guidelines and consult with your healthcare professional to ensure proper use of the FreeStyle Precision Neo system.
Does FreeStyle precision neo measure ketones?
Yes, the FreeStyle Precision Neo meter is capable of measuring blood ketone levels in addition to blood glucose levels.
Using the SaveHealth discount card, what is the price of Freestyle Precision Neo System without insurance?
Using the SaveHealth discount card, the price of Freestyle Precision Neo System without insurance is $23.80.
What is the price of Freestyle Precision Neo System at Walgreens?
The price of Freestyle Precision Neo System at Walgreens is $23.80. SaveHealth can help you save 70% on Freestyle Precision Neo System at Walgreens.