
Minimed 630g Insulin Pump Coupons & Savings Card – Discount Prices from $9991.35
My prescription
Edit
1, Minimed 630g Insulin Pump (1 Kit)
Select pharmacy

CVS
$9991.35
COUPON PRICE
Walmart
$10228.71
COUPON PRICE
Walgreens
$10239.70
COUPON PRICEMinimed 630g Insulin Pump savings card
Show this card to your pharmacist
CVS
$9991.35
BIN
ID
PCN
GRP
019876
LHFEB5D973
CHIPPO
LHX
Powered by
Price history for Minimed 630g Insulin Pump
1 Kit, 1
Average retail price for Minimed 630g Insulin Pump
Average SaveHealth price for Minimed 630g Insulin Pump
Our price history data is based on aggregated prescription data collected from participating pharmacies in America. Our prescription data updates daily to reflect the latest price changes. If you notice a missing data point, it means there wasn't sufficient data available to generate a monetary value for that date.
*Retail prices are based on pharmacy claims data, and may not be accurate when we don't have enough claims.
Minimed 630g Insulin Pump dosage forms
Dosage | Quantity | Price from | Per unit |
---|---|---|---|
1 | 1 Kit | $9991.35 | $9991.35 |
Minimed 630g Insulin Pump Warnings
The MiniMed™ 630G insulin pump is a sophisticated device designed to assist individuals in managing diabetes through continuous insulin delivery. While it offers significant benefits, users should be aware of certain risks associated with its use to ensure safety and effectiveness.
Device Malfunctions and Physical Damage
Physical impacts, such as dropping or bumping the pump, can damage critical components like the retainer ring. A compromised retainer ring may prevent the insulin reservoir from locking properly, potentially leading to incorrect insulin delivery. This can result in either too much or too little insulin being administered, increasing the risk of hypoglycemia (low blood sugar) or hyperglycemia (high blood sugar). Regularly inspect your pump for signs of damage, especially after any physical impact. If you notice issues with the retainer ring or reservoir connection, discontinue use and contact Medtronic for assistance.
Battery and Power Issues
The pump's battery cap is essential for maintaining a secure power connection. If the metal contact within the battery cap becomes loose or detached, it can lead to power loss, causing the pump to stop insulin delivery. This interruption can result in elevated blood sugar levels and, in severe cases, diabetic ketoacidosis (DKA). To mitigate this risk, regularly check the battery cap for signs of wear or damage. Always carry spare batteries and replace them promptly when alerted by the pump.
Environmental Considerations
Exposure to strong magnetic fields, such as those from MRI machines, can interfere with the pump's operation. Before undergoing medical procedures involving such equipment, remove your pump, sensor, transmitter, and meter to prevent potential malfunctions. Additionally, avoid exposing the pump to extreme temperatures, as both high and low temperatures can affect insulin potency and device performance.
User Suitability
Insulin pump therapy requires active participation and regular monitoring. It is not recommended for individuals unwilling or unable to perform at least four blood glucose tests per day or those who cannot maintain regular contact with their healthcare provider. Adequate vision and hearing are necessary to recognize pump signals and alarms. If you have concerns about your ability to manage the pump effectively, consult with your healthcare professional to determine if this therapy is appropriate for you.
By understanding and addressing these risks, users can enhance the safety and effectiveness of the MiniMed™ 630G insulin pump in their diabetes management regimen.
Minimed 630g Insulin Pump Side Effects
The MiniMed 630G insulin pump is designed to assist individuals with diabetes in managing their insulin delivery. While it offers significant benefits, users should be aware of potential side effects and safety considerations associated with its use. Hypoglycemia and Hyperglycemia: The primary risks involve the delivery of insulin, which can lead to low blood sugar (hypoglycemia) or high blood sugar (hyperglycemia). These conditions can result from various factors, including device malfunction or user error. Severe cases may lead to serious health complications. Infusion Site Issues: Users may experience localized reactions at the infusion site, such as infection, skin irritation, redness, bruising, discomfort, pain, bleeding, rash, or swelling. It's important to monitor these sites regularly and consult a healthcare professional if any adverse reactions occur. Device Malfunctions: There have been reports of issues with the pump's retainer ring, which secures the insulin reservoir. A damaged or missing retainer ring can lead to incorrect insulin dosing, potentially causing hypoglycemia or hyperglycemia. Users are advised to inspect the retainer ring regularly and contact the manufacturer if any damage is detected. Sensor Interference: The continuous glucose monitoring (CGM) sensor used with the MiniMed 630G can be affected by certain medications containing acetaminophen. This interference may result in inaccurate glucose readings. Users should be cautious when taking such medications and verify glucose levels with a blood glucose meter before making treatment decisions. Environmental Considerations: Exposure to strong magnetic fields, such as those from MRI machines, can damage the pump's internal components, potentially leading to incorrect insulin delivery. Users should remove the pump before undergoing any procedures involving strong magnetic fields. To minimize these risks, it's essential for users to receive proper training on the device, perform regular blood glucose monitoring, and maintain open communication with their healthcare providers.
Minimed 630g Insulin Pump Interactions
When using the MiniMed™ 630G insulin pump, it's important to be aware of potential interactions with other devices and substances to ensure safe and effective operation.
Electronic Devices and Magnetic Fields
The MiniMed™ 630G insulin pump should not be used near certain electronic equipment that may interfere with its normal operation. This includes mobile communication devices such as cell phones, GPS navigation systems, anti-theft systems, and any electrical equipment with an output transmitter power greater than 1 watt. To minimize the risk of interference, maintain a separation distance of at least 12 inches between the insulin pump and these devices. Additionally, avoid exposing the pump to strong magnetic fields, such as those generated by MRI machines, x-ray equipment, or CT scanners, as these can cause the pump to malfunction. Always remove your pump, sensor, transmitter, and meter before entering areas with such equipment.
Medications Containing Acetaminophen
If you are using the continuous glucose monitoring (CGM) feature of the MiniMed™ 630G system, be cautious when taking medications that contain acetaminophen (commonly found in pain relievers like Tylenol). Acetaminophen can cause falsely elevated sensor glucose readings. The degree of inaccuracy depends on the amount of acetaminophen in your system and may vary between individuals. Always verify your glucose levels using a blood glucose meter before making any therapy adjustments when acetaminophen is active in your body.
Infusion Sets and Reservoirs
Use only Medtronic-manufactured reservoirs and infusion sets with your MiniMed™ 630G insulin pump. Using non-Medtronic reservoirs or infusion sets may interfere with proper pump operation and is not recommended. Do not modify your reservoir or infusion set, as this can cause serious injury, interfere with device operation, and void your warranty.
Environmental Conditions
Avoid exposing your pump to extreme temperatures. Do not expose your pump to temperatures above 104°F (40°C) or below 41°F (5°C), as this may damage your device. Insulin solutions freeze near 32°F (0°C) and degrade at high temperatures. If you are outside in cold weather, wear your pump close to your body and cover it with warm clothing. If you are in a warm environment, take measures to keep your pump and insulin cool.
By being mindful of these interactions and following the recommended guidelines, you can help ensure the safe and effective use of your MiniMed™ 630G insulin pump.
How much is the Medtronic MiniMed 630G system?
The cost of the Medtronic MiniMed 630G system can vary depending on factors such as insurance coverage, location, and any additional accessories or supplies needed. It is recommended to contact Medtronic directly or consult with a healthcare provider or insurance company to get an accurate estimate based on individual circumstances.
How much does a Medtronic insulin pump cost?
The cost of a Medtronic insulin pump can vary depending on several factors, including the specific model, insurance coverage, and location. Generally, the price can range from approximately $4,000 to $7,000 without insurance. It is advisable for individuals to check with their insurance provider and local medical suppliers for more precise pricing and coverage details.
What is Medtronic 630G?
The Medtronic 630G is an insulin pump system designed for individuals with diabetes. It helps manage blood glucose levels by delivering precise doses of insulin throughout the day. The system includes features such as customizable basal and bolus insulin delivery, a user-friendly interface, and integration with continuous glucose monitoring (CGM) for enhanced diabetes management.
What is the difference between Medtronic 630G and 780G?
The Medtronic 630G and 780G are both insulin pump systems, but they have some key differences. The 630G is an earlier model that provides continuous insulin delivery and features SmartGuard technology, which can suspend insulin delivery when glucose levels are predicted to drop. The 780G, on the other hand, is a more advanced system that includes an automated insulin delivery feature. It uses the SmartGuard algorithm to automatically adjust insulin delivery based on continuous glucose monitoring, aiming to maintain glucose levels within a target range. The 780G also offers Bluetooth connectivity for easier data sharing and remote monitoring.