Minimed Mio Advance Infuse Set coupons
Minimed Mio Advance Infuse Set

Minimed Mio Advance Infuse Set Coupons & Savings Card – Discount Prices from $709.76

The MiniMed Mio Advance infusion set is designed to simplify insulin pump therapy with its all-in-one, pre-loaded inserter that allows for quick, one-handed insertion in just four steps: peel, pinch, place, and press. This user-friendly design features a 90-degree soft Teflon cannula available in 6 mm and 9 mm lengths, with tubing options of 23 inches and 43 inches to accommodate different needs. The needle remains hidden before, during, and after insertion, which can help reduce anxiety for users. An audible "click" confirms a secure connection, and the set is compatible with insulin pumps that have Luer-lock or MiniMed connections, including those from Medtronic, Roche, and Animas. This infusion set is particularly beneficial for individuals with dexterity challenges or needle apprehension.
Our Minimed Mio Advance Infuse Set coupons are free to use. You can print the coupon, email it to yourself, or receive the Minimed Mio Advance Infuse Set coupon via text message. To get your free discount, show the pharmacist your Minimed Mio Advance Infuse Set savings card which has the discounted coupon price. Use our filters below to edit the prescription box to match your needs. The Minimed Mio Advance Infuse Set prices will update based on your prescription needs. Above our Minimed Mio Advance Infuse Set coupons, you can change the location to see pharmacy prices in other areas. Our prescription discount card will update online with the specific pharmacy costs associated with your edits. Be sure to text, email, or print the Minimed Mio Advance Infuse Set savings card code that you need after editing the prescription box and location field. Show the discount card to your pharmacist before paying.

My prescription

Edit

1, Minimed Mio Advance Infuse Set (30 Miscellaneous)

Select pharmacy

Pharmacy logo

CVS

$709.76

COUPON PRICE
Pharmacy logo

Walgreens

$719.33

COUPON PRICE
Pharmacy logo

Walmart

$720.40

COUPON PRICE
Pharmacy logo

Albertsons

$727.52

COUPON PRICE

Minimed Mio Advance Infuse Set savings card

Show this card to your pharmacist
Pharmacy logo

CVS

$709.76

BIN

ID

PCN

GRP

019876

LH42DD7D2C

CHIPPO

LHX

Powered by

This card is not insurance

Price history for Minimed Mio Advance Infuse Set

30 Miscellaneous, 1

Average retail price for Minimed Mio Advance Infuse Set

Average SaveHealth price for Minimed Mio Advance Infuse Set

Our price history data is based on aggregated prescription data collected from participating pharmacies in America. Our prescription data updates daily to reflect the latest price changes. If you notice a missing data point, it means there wasn't sufficient data available to generate a monetary value for that date.

*Retail prices are based on pharmacy claims data, and may not be accurate when we don't have enough claims.

Minimed Mio Advance Infuse Set dosage forms

Use our Minimed Mio Advance Infuse Set 1 coupon with prices from $709.76 for 30 Miscellaneous.
DosageQuantityPrice fromPer unit
130 Miscellaneous$709.76$23.66

Minimed Mio Advance Infuse Set Warnings

When using the MiniMed™ Mio™ Advance infusion set, it's important to be aware of certain risks to ensure safe and effective insulin delivery:

  • Accidental Insulin Delivery: Always disconnect the infusion set from your body before rewinding the pump or filling the tubing. Failing to do so may result in unintended insulin infusion, potentially leading to low blood sugar levels.

  • Insertion Site Issues: Improper insertion or maintenance can cause inaccurate insulin delivery, infection, or irritation at the site. Before inserting, clean the area with isopropyl alcohol and ensure the soft cannula is fully inserted. Regularly check the site for signs of inflammation or dislodgement.

  • Tubing Blockages: If insulin or any liquid enters the tubing connector, it can block the vents needed for proper priming, leading to incorrect insulin delivery. To prevent this, hold the insulin vial upright when removing the reservoir from the transfer guard. If liquid gets on the reservoir or inside the tubing connector, replace both the reservoir and infusion set.

  • Storage Conditions: Store infusion sets in a cool, dry place at room temperature. Avoid direct sunlight and humid environments, as these conditions can compromise the integrity of the infusion set.

  • Single Use Only: Each infusion set is designed for single use. Reusing the set can damage the cannula or needle, increasing the risk of infection, site irritation, and inaccurate insulin delivery.

  • Proper Disposal: After use, dispose of the infusion set and introducer needle safely in a sharps container, following local regulations.

By adhering to these guidelines, you can minimize potential risks associated with the MiniMed™ Mio™ Advance infusion set and maintain effective diabetes management.

Minimed Mio Advance Infuse Set Side Effects

The MiniMed Mio Advance infusion set is designed to deliver insulin subcutaneously through an insulin pump. While it offers convenience, users may experience certain side effects or issues. Skin Irritation and Infection: Improper insertion or maintenance of the infusion site can lead to skin irritation or infection. It's essential to clean the insertion area with isopropyl alcohol before inserting the infusion set. If the site becomes inflamed, replace the set and use a new site until the area has healed. Insertion Discomfort: Some users have reported discomfort during insertion, including stinging or burning sensations. This may be due to factors like skin sensitivity or the insertion technique. Ensuring the skin is warm and applying adequate pressure during insertion can help reduce discomfort. Cannula Issues: The soft cannula may crimp or bend during application or while wearing, potentially limiting or preventing insulin delivery. If you suspect a crimped or bent cannula—indicated by difficulty pressing down on the syringe plunger, medication leaking onto the skin, or moisture inside the device—remove and discard the infusion set immediately. Tubing Disconnection: There have been instances where the tubing disconnects from the cannula unexpectedly, leading to high blood glucose levels. It's important to ensure that the tubing is securely connected and to monitor blood glucose levels regularly to detect any issues promptly. Insulin Delivery Interruptions: If insulin or any liquid gets inside the tubing connector, it can temporarily block the vents that allow the pump to properly fill the infusion set. This may result in the delivery of too little or too much insulin, leading to hyperglycemia or hypoglycemia. If this occurs, start over with a new reservoir and infusion set. To minimize these risks, follow the manufacturer's instructions carefully, rotate insertion sites regularly, and consult with your healthcare professional if you experience persistent issues.

Minimed Mio Advance Infuse Set Interactions

The MiniMed™ Mio™ Advance infusion set is compatible with insulin pumps that have Luer-lock or MiniMed™ connections, including those from Medtronic, Roche, and Animas. This compatibility allows users to select from a range of insulin pumps that suit their individual needs.

The infusion set features a 90-degree soft Teflon cannula, available in 6 mm and 9 mm lengths, catering to different body types and insertion preferences. The tubing is offered in 23-inch and 43-inch lengths, providing flexibility in pump placement.

The Mio Advance is designed with a pre-loaded inserter, simplifying the insertion process into four steps: peeling the adhesive, removing the safety pin, placing the device on the skin, and pressing the button to insert. This design is particularly beneficial for individuals with dexterity issues or needle anxiety.

To ensure optimal insulin absorption and prevent set obstruction, it is recommended to change the Mio Advance infusion set and reservoir every two to three days, or as directed by a healthcare professional.

When changing the infusion set, it's crucial to confirm that the infusion set tubing is disconnected from the body before placing the reservoir into the pump, rewinding the pump, loading the reservoir, or filling the infusion set tubing. Failing to do so may result in an accidental infusion of insulin, potentially causing hypoglycemia.

Additionally, if insulin or any liquid gets on the top of the reservoir or inside the tubing connector, it can temporarily block the vents that allow the pump to properly fill the infusion set. This may result in the infusion of too little or too much insulin, leading to hyperglycemia or hypoglycemia. If this occurs, start over with a new reservoir and infusion set.

By adhering to these guidelines and precautions, users can effectively manage their insulin therapy using the MiniMed™ Mio™ Advance infusion set.

Minimed Mio Advance Infuse Set FAQs
How much does it cost to fill a Medtronic Mio Advance cannula?

The cost to fill a Medtronic Mio Advance cannula can vary depending on several factors, including the pharmacy or supplier, insurance coverage, and geographic location. It is recommended to check with local pharmacies or medical supply companies for the most accurate pricing. Additionally, contacting the insurance provider can help determine any coverage or out-of-pocket costs.

Using the SaveHealth discount card, the price of Minimed Mio Advance Infuse Set without insurance is $709.76.

The price of Minimed Mio Advance Infuse Set at CVS is $709.76. SaveHealth can help you save 72% on Minimed Mio Advance Infuse Set at CVS.

The price of Minimed Mio Advance Infuse Set at Walgreens is $719.33. SaveHealth can help you save 72% on Minimed Mio Advance Infuse Set at Walgreens.

The price of Minimed Mio Advance Infuse Set at Walmart is $720.40. SaveHealth can help you save 72% on Minimed Mio Advance Infuse Set at Walmart.